Mark-10, SFCOMP-1, Complete Options Package, ESM1500S / ESM750S, Download
Part No: SF008
Crosshead movement responds to manually pushing or pulling on the force gauge shaft or load cell. Increasing force produces greater speeds. Ideal for setups and quick positioning.
Requirements:Series 7 or 5 gauge or indicator
Part No:SF009-1 (ESM1500S / ESM750S)
Position is indicated on the control unit display, with output via USB. An internal scale utilizing Renishaw technology produces significantly higher accuracy than with conventional rotary encoder-based designs. Backlash and nonlinearity are virtually eliminated.
Part No: SF010
Fully control the stand and force gauge / indicator via custom-written application in any language supporting ASCII communications. Also responds to the legacy Chatillon TCD command set and legacy Nexygen TCD software (not available from Mark-10). This option is not required for MESUR™gauge Plus software
Requirements:- Series 7 or 5 gauge or indicator, SF009 travel indication
Part No: SF011
The stand stops at or cycles between upper and lower travel distances.
Requirements:SF009 travel indication
Part No: SF012
Protects a force gauge or force sensor against overload. Also compatible with many competitors’ gauges.
Requirements:Series 7 or 5 gauge or indicator
Part No: SF013
The crosshead moves to a limit switch, force set point, travel position, or break, then stops and reverses direction at full speed to the opposite limit.
Requirements:- To reverse at specified force: Series 7 or 5 gauge or indicator; To reverse at travel limit: SF011 travel limits; To reverse at break: SF019 break detection
Part No: SF014
Same as auto-return, but programmable up to 99,999 cycles. Programmable dwell time at upper and lower limits up to 9,999 seconds.
Requirements:Same as auto-return, at the same speed in each direction. Add SF016 for independent up and down speeds.
- Independent up and down Speeds
Part No: SF016
Individually specify speeds for the up and down directions
- Low speed range extension
Part No: SF017
Extends the standard speed range down to 0.001 in/min (0.02 mm/min).
Requirements:- To reverse at specified force: Series 7 or 5 gauge or indicator; To reverse at travel limit: SF011 travel limits; To reverse at break: SF019 break detection
- High speed range extension
Part No: SF018 (ESM1500 / ESM1500S)
Extends the max speed to 90 in (2,300 mm)/min
Part No: SF019
Crosshead stops at a programmable drop in force.
Requirements:- Series 7 or 5 gauge or indicator
Part No: SF020
Dynamically adjusts the crosshead position to maintain a specified load for an indefinite or specified period of time.
Requirements:- Series 7 or 5 gauge or indicator; If a specified time is required, order SF014 cycling / dwell time
Part No: SF021
Stops the crosshead and/or zeroes the travel display at an initial preload - useful in tensile, spring, elongation, and other applications.
Requirements:SF009 travel indication; Series 7 or 5 gauge or indicator
Part No: SF022
Save and recall sets of test parameters, such as speeds, travel limits, preload, etc. Maximum of 50 profiles may be stored.