TPI Combustion Efficiency Analyzer 708A740 with Infrared Printer 0 - 10000 ppm
Includes
- TPI 708 Instrument
- Infrared printer (A740)
- Rubber Boot (A765)
- Soft Carrying Case (A768)
- Flue Sampling Probe (A770)
- In-Line Filter assembly installed on Flue probe (A794)
- Temperature Probe (GK11M)
- Mini Pump Protection Filter Assembly and spare filters (A763)
- Exhaust Spigot (removable) (A764)
- Instruction Manual
The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.
Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
Determine combustion efficiency, CO2, and CO air free. Some models include built-in differential manometer, combustible gas detection, PC communication, data logging, and can measure NO / NOX.
Features
- Measure CO, and temperature
- Calculate CO2, efficiency, excess air, and CO air free
- Pump driven for fast response
- Will not shut off if 15 ppm CO is present for increased safety
- Ten selectable fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
- Optional A740 IR printer available for hard copies of test results
- Built-in differential thermometer
- Store function to save up to 50 readings
- Large easy to read backlit display
Applications
- Tuning of residential and furnaces and domestic boilers
- Ambient and stack testing for CO
- CO safety measurements in and around combustion sources
- Temperature checking, including superheat and hydronic differential temperatures