Temperature Measurement |
Flue Temperature Range | 32° to 1112°F (0° to 600°C) |
Flue Temperature Resolution | 1°F/C |
Flue Temperature Accuracy | +3.6°F +0.3% rdg |
Inlet Temperature (Internal Sensor) Accuracy | +1.8°C +0.3% rdg |
Inlet Temperature (External Sensor) Accuracy | +3.6°F +0.3% rdg |
Flue Gas Measurement |
Oxygen Range | 0 to 21% |
Oxygen Resolution | 0.1% |
Oxygen Accuracy | +0.3% |
Carbon Monoxide Range | 100 to 400ppm, 400 to 2,000ppm, 2,000 to 9,999ppm, Above 10,000ppm purge pump operates |
Carbon Monoxide Resolution | 1ppm |
Carbon Monoxide Accuracy | ±5ppm, ±20ppm, ±5%, ±10%, Unspecified |
Carbon Dioxide Range | 0 to 20% |
Carbon Dioxide Resolution | 0.1% |
Carbon Dioxide Accuracy | ±0.3% volume |
Efficiency (Net or Gross) Range, Resolution, Accuracy | 0 to 20%, 0.1%, +1.0% rdg |
Efficiency High (C) Range, Resolution, Accuracy | 0 to 99.9%, 0.1%, +1.0% rdg |
Excess Air Range, Resolution, Accuracy | 0 to 250%, 0.1%, +0.2% rdg |
CO/CO2 ratio Range, Resolution, Accuracy | 0 to 0.999%, 0.0001, +5% rdg |
Pre-Programmed Fuels | Natural Gas, Propane, Butane, LPG, Light Oils (28/35sec), Wood Pellets, Town Gas, Coke Gas, Bio Oil, Bio Gas |
Certification | The C165+ is independently tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BlmSchV) |
CE Conformity | Yes |
RoHS | EC62321-2:2013, IEC62321-1:2013, IEC62321-3-1:2013, IEC62321-5:2013, IEC62321-4:2013, IEC62321-7-2:2017, IEC62321-7-1:2015, IEC62321-6:2015 |
REACH Compliant | Yes |
AHRI 1260 Standard | Yes |
Certification | The C161 is independently tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BlmSchV) |
EMC | EN50270:2015 |
Safety | EN61010-1:2010 |